What is the room temperature of DD series air cooler supporting frozen product warehouse?
DD series air coolers are optimized for medium greenhouse, and the working range is-2 C to-18 C, which are used to store meat, fish and frozen food.
Within its rated range, DD has a blade separation of 4.5-6.0 mm, aiming at balancing heat transfer and frost resistance. The indoor temperature is 10°C and the humidity is 80%RH, which can maintain continuous operation for 6-10 hours before starting the defrosting cycle. This interval is shortened to 4-6 hours when approaching the lower limit of-18 C.
Its effective capacity varies greatly according to the working temperature of the refrigerating room. At-5 C, the device provides about 94% catalog power; When the temperature reaches-18 C, its actual capacity drops to 71% of the rated value. This correction factor must be applied in the installation dimension calculation stage.
DD series coolers offer two main thawing options: standard electrolysis or upgrading to D series hydrolytic air coolers. The hydrolysis model can shorten the downtime of each cycle to 12-18 minutes, while the electrolysis time is 25-40 minutes. This improvement is very useful for industrial cameras that stop for a short period of 24 hours.
Continuous use of DD below-18 C is not recommended. If forced to operate at-22 C, the frost will accelerate significantly and the melting interval will be shortened to less than 3 hours. According to the data of xindacool, overclocking can shorten the service life of equipment by 35% and increase the energy consumption of refrigeration system by 28%.
DD supports commonly used refrigerants R22, R404A and R507A which are widely used in industrial refrigeration equipment. Ammonia used for NH3 without factory preparation; To use ammonia, DJ series of heat exchange materials with chemical corrosion resistance should be selected. Modifying existing DD devices is not a best practice.
In practical facilities, attention should be paid to the moisture generated by stored products. If the temperature exceeds-10 C, it will temporarily increase the humidity and frost. Under these conditions, it is suggested to reduce the load at the entrance of batch to avoid saturating the thawing capacity of evaporation equipment.
When paired with FNH, FNV or FNVT air-cooled capacitors, the actual correction capacity of DD should be taken and a safety margin of 15% should be added. Without room temperature correction, catalog power should not be used directly, because it will make the capacitor size too small and cause problems when it is hot in summer.
FAQ
What is the rated temperature range of DD series coolers? The rated working range of the freezer is-2 C to-18 C.
How much did your actual capacity decrease when working at-18 C? At a-18 C, its effective capacity is only 71% of the directory value.
Can DD be upgraded to D series hydrolysis system? Yes, the D series hydrolysis version is suitable for DD drives with short cycle time.
Can DD be used continuously below-18 C? Not recommended; It shortens the service life and greatly increases the energy consumption.
Does DD cooler support NH3 ammonia refrigerant? No, ammonia needs DJ series models with anti-corrosion materials.
What allowance is used to determine the condenser size of DD evaporator? Apply a minimum deposit of 15% to the adjusted actual equipment capacity.
Integrated keywords: DD series air cooler, fin separation, thawing cycle, D series hydrolysis cooler, FNH air condenser, FNV air condenser, FNVT air condenser, cooling chamber temperature, R404A,R507A.
Address: No. 866, Putian Avenue, Sanjiang Sub-district, Shengzhou City, Zhejiang Province
Mobile phone: +86 13567599011
Landline: 0575-83268796
Email:michelle@xindacool.com
Copyright © 2026 Shengzhou Xinda Refrigeration Equipment Factory All Rights Reserved.