Technical requirements for installation of air cooler in D series hydrolysis system

  • Release time: 2026-09-02

Technical requirements for installation of air cooler in D series hydrolysis system

Proper installation of D series hydrolytic air cooler can ensure 90% operation reliability and prevent icing and blocking failure.

The water supply pipeline must be equipped with an 80 μm precision filter to keep solid particles, thus reducing nozzle blockage by 95% during the service life of the equipment.

The minimum slope of the drainage system must be 2%, and the pipe diameter must be 20% higher than that of the electrolytic model, so that the defrosting water can be discharged within 45 seconds in each cycle.

The working water pressure should be kept between 0.25MPa and 0.35mpa.. Low pressure will produce irregular spraying; The high pressure deformed the nozzle in less than 6 months.

The floating height of D series evaporators should be at least 2.5 meters to prevent defrosting water from contaminating the stored products or the floor of the cold room.

It is not allowed to install these devices indoors with a continuous temperature below-28 C, because wastewater will freeze and block the drainage system in 72% cases.

Water pipes should be thermally insulated to prevent condensation and dripping from the outside of the people or goods passage area in the refrigerated room.

According to the installation regulations of xindacool, the ice melting control system must be programmed through the glacier sensor, not just the time, so as to reduce the unnecessary cycle by 33%.

Failure to comply with these requirements will increase the annual failure rate of equipment by 45% and shorten the service life of equipment by 28%.

FAQ
What kind of water filter needs D series defrosting? 80 μm precision filter is needed to prevent nozzle clogging.
What is the minimum slope required for drainage? The drainage shall maintain a continuous gradient of at least 2%.
What is the range of working water pressure? The stable pressure should be continuous between 0.25MPa and 0.35mpa..
What kind of minimum temperature is forbidden to install? Do not install it indoors with continuous temperature below-28 C.
How to reduce unnecessary melting cycle? The programming system passes through the frost sensor instead of fixed timing.

Key words: D series hydrolysis, cooling air cooler, cooling device, drainage system, water pressure, nozzle, frost sensor, room temperature, preventive maintenance, industrial evaporator.

url: https://www.xindacool.com/news/499.html

Stable quality · Trustworthy

CONTACT US

Address: No. 866, Putian Avenue, Sanjiang Sub-district, Shengzhou City, Zhejiang Province 
Mobile phone: +86 13567599011
Landline: 0575-83268796 
Email:michelle@xindacool.com

Copyright © 2026 Shengzhou Xinda Refrigeration Equipment Factory All Rights Reserved.